Power
Systems International Ltd announces six new low power
inverters of 500VA and 1000VA capacity from its’
successful Miniverter rack mounting series. The Miniverter
WM (wave shaped modulated) series 1600 inverters is
a compact, rugged design for use with mobile or fixed
station 19” or 23” communications rack installations
for all types of telecommunications and broadcasting
service applications. This inverter range is available
for use with 48V DC battery installations but models
are available for 24V DC and 120V DC operation. Output
is 230V 1 phase 50Hz and 120V 1 phase 60Hz models are
also available. Enclosure class is IP20, each model
occupies only 2U of vertical rack space. Natural ventilation
by convection cooling is used in the design as the generated
heat is low due to the high efficiency eg. 88% for the
1000VA model. Operation at an ambient temperature of
50°C can easily be accommodated in the standard
model without the need for derating. A novel on line/standby
option is available through an automatic bypass mode
feature. In standby mode (L) the bypass circuit mains
line feeds the load and the inverter operates in “Synch
Standby” with mains and draws only 1 Amp from
the station battery. Upon loss of mains supply, the
auto bypass transfers the load to the inverter, the
station battery supplies the inverter and the critical
load. The inverter is always connected to the station
battery hence there is no interruption or disturbance
to the critical load during the bypass transfer function.
The operational noise level of the inverter is hardly
audible at 50dBA and at a weight of about 10kg this
is a compact, lightweight rack mounting unit with impeccable
credentials for performance and reliability.
WM Series
1650 Inverters
500VA and 1000VA, 50Hz or 60Hz
For mobile and base station communications, avionics,
naval and other defence security applications where
a rugged industrial construction is demanded.
- 2U high
- 19” and 23” rack enclosure mounting
- High efficiency
- Convection cooled
- Light weight
- Multi mode operation
- Audible noise level <50dBA
- High crest factor, non-linear load handling capability
SMArt
Photovoltaic inverters up to 3500 watts for use with
solar panels can be connected in 3 phase or multi module
single phase output to supply the local power grid,
or can operate with batteries on remote sites.
Specification
| Input
voltage |
As shown in the selection table |
| Current |
As shown in the selection table |
| Output |
230V 1 Phase + neutral, 120V option |
| Output
frequency |
50Hz +/-0.15Hz, 60Hz option |
| Capacity |
Rated VA at 0.8 Power Factor |
| Output
voltage regulation |
+/-3% from no load to full load over input voltage
range |
| Output
waveform |
Quasi sine wave with regulated RMS and peak voltages |
| DC
input filter |
C message weighted, noise reflected into typical
battery
source <32dBmC, meets CCITT prescriptions |
| Environment |
Dust free, damp free in well ventilated enclosure
where
ambient temperature does not exceed 0°C to 50°C |
| Audible
Noise |
<50dBA at 1 metre |
Dimensions

Weights
500VA - 17kg
1000VA - 11kg
Options
- 3U aluminium front fascia plate with handles
- 2U power management and
by-pass module supplied
with LED status indicating
mimic or with metering
- 2U rectifier charger modules
up to 50A 48V, 24V and
110V versions available
- Fully integrated rack
enclosures fitted with
rectifier, inverter bypass and
batteries available
- Special execution
Miniverters are available
with seismic qualification for
Nuclear Power Stations and
defence vehicle installation
- Interconnection cables
between modules fitted
with industrial grade plugs
and socket arrangement
Miniverter® is a registered trade mark of Power
Systems International Limited
| |
Nominal
Input
V DC |
Input
Range
V DC |
Input
Current
No Load
A DC |
Input
Current
Full Load
A DC |
Efficiency
% |
Heat
Output
Btu/hour |
Model
WM |
| 500VA |
24
48
120 |
21-29
42-58
105-140 |
0.58
0.35
0.15 |
29.0
14.0
5.7 |
82
85
83 |
375
290
335 |
1653-24
1653-48
1653-120 |
| 1000VA |
24
48
120 |
21-29
42-58
105-140 |
0.33
0.16
0.09 |
55.0
26.9
10.5 |
87
88
91 |
529
443
350 |
1654-24
1654-48
1654-120 |
| NOTES |
- No load input current is typical
at nominal input voltage.
- Input current, efficiency
and heat output are typical at full load and
at
minimum input voltage.
- See specification for model
numbering suffix details.
|
Protection
Protection against short duration overloads and accidental
short circuit of the output is provided electronically.
Recovery is automatic upon removal of the fault condition.
Where overload or short circuit conditions are sustained
for 10 seconds the electronic protection will trip the
front panel circuit breaker which is in series with
the DC input. This circuit breaker also provides protection
against accidental reversed input voltage polarity during
installation. The 48V DC input inverters have the circuit
breaker installed in the -ve DC input line, whilst the
24V and 120V input units have the breaker in the +ve
DC line. The inverter will automatically shut down if
subjected to a DC input undervoltage condition and will
restart and revert to normal operation upon restoration
of input voltage within the prescribed limits. Excessively
high input DC voltages and repetitive cyclic peak voltages
outside the prescribed limits will eventually trip the
front panel circuit breaker.
Controls
and Indicators A combined circuit breaker
and on/off switch is provided on the front panel. This
switches the input DC power to the inverter. The WM
Series inverter, suffix “U” are provided
with an AC line fuse in the bypass circuit and the inverter
operational status is indicated by LED’s.
Mechanical
Construction
The Miniverter enclosure is constructed
from a press formed steel frame, the top and bottom
covers are made from plated and perforated aluminium.
The optional front panel is made from heavy gauge aluminium.
Terminals are provided on the rear panel and a protective
cover is fitted for safety. When used in conjunction
with the separate Miniverter Power Management and Bypass
Module, an optional plug and socket arrangement with
flexible cables can be provided.
STANDARD CONFIGURATIONS
Miniverter
WM Series, “U” version
In this mode the load is normally powered
by the inverter “active on-line”. If the
inverter output is degraded, the bypass circuit will
be initiated to transfer the load from the inverter
to the AC power source. The transfer of a critical load
to the bypass AC power source will not be detected even
by highly sensitive loads. Upon restoration of power
from the inverter, the inverter will stabilize its output
against a logic reference and after about 4 seconds
will reverse transfer the critical load from the bypass
unit to the inverter. Auxiliary contacts are provided
for signalling alarm conditions and status to remotely
located mimic panels, building management systems and
control rooms. The operational status of the inverter
is also shown on the LED’s on the front panel.
Miniverter
WM Series, “L” version
The inverter operates in a “passive off-line”
mode on standby whilst the critical load is fed through
the bypass circuit from the AC power source i.e. “mains
line”. The inverter is connected to the battery
source and its quiescent current on no load is less
than 1 Amp to keep the logic fully operational. Hence
in this mode the battery in the communications station
remains fully charged and the rectifier would not have
to be sized to support the permanent current as drawn
from the battery by the on line “U” version.
Upon loss of input mains, or where the AC line voltage
and/or frequency are out of tolerance, the inverter
will operate from the station battery
High
power industrial inverters
Inverters with 48V DC input are available in single
phase output from 3kVA to 30kVA and three phase output
from 7.5kVA to 50kVA - details on request.
|